Mix designs / Cellular

Cellular Grout 27 PCF + Base Slurry 108 PCF

~107 psi (27 PCF) · N/A · Cellular grout / annular fill

Celebrating America’s 250th Anniversary (1776–2026)

When to use

The lightest published Volume cellular fill — 27 PCF, about 82% foam, ~107 psi. Same 108 PCF neat-cement base slurry as the rest of the cellular family. Annular space, abandoned pipe, void fill, and low-pressure foundation backfill.

Key specs

  • Cellular grout 27.0 PCF — approximately 107 psi
  • Foam 81.6% ± 2.5 by volume
  • Base slurry 108 PCF neat cement (unchanged)
  • Cement 266 / water 172 / sand 283 lbs per yd³
  • 28-day psi scaled from 180 × (density/38.2)^1.5
  • Aerix foam · Type IL Ash Grove Durkee · Estacada sand
  • Annular space / abandoned pipe / void fill — not structural concrete